重量法是国内外监测大气颗粒物质量浓度的经典方法。本文对国内各级环保部门所属环境监测机构开展颗粒物重量法滤膜称量工作现状调研,并结合国内外方法标准和技术规范等文献调研,重点探讨了手工监测中滤膜称量技术要点,如称量实验室环境、称量设备和称量影响因素等技术,基于环境管理与环境监测需求对大气颗粒物手工监测滤膜称量提出相关建议。
引文
[1]2015中国环境状况公报(hup://www.mep.gov.cnhomejrtt_1/201606/W020160602419515164060.pdf)
    [2]Che Huizheng,Zhang Xiaoye,Li Yang,Zhou Zijiang,Qu John J,Hao Xianjun.Haze trends over the capital cities of 31 provinces in China,1981-2005[J].Theoretical and applied Climatology,2009,97(3):235-242.
    [3]2015年74城市空气质量状况报告[R].
    [4]V.Ramanathan,G.Carmichael.Global and regional climate changes due to black carbon[J].Nature Geoscience,2008,1,221-227
    [5]Ulla Makkonen,HeidiHellen,Pia Anttila,Martin Ferm.Size distribution and chemical composition of airborne particles in south-eastern Finland during different seasons and wildfire episodes in 2006[J].Science of Total Environment,2010,408(3):644-651.
    [6]Andre NeL Air pollution-related illness:effects of particles[J].Science,2005,308(5723):804-806.
    [7]王晓彦,李健军.欧洲大气颗粒物标准及监测体系[J].中国环境监测,2014,30(6):13—18.
    [8]Rainer Balhorn,Dieter Buer,et al.Determination of mass,Part 1:Dissemination of the unit of mass-balances,weights and test room[S].PTB-Bericht,PTB-MA-24e,Braunschweig,June 1996.
    [9]HJ 618—2011环境空气PM_(10)和PM_(2.5)的测定重量法[S].
    [10]US EPA.Appendix L to Part 50—Reference method for the Determination of Fine Particulate Matter as PM_(2.5)in the Atmosphere[S].
    [11]Michael Glaser.Advices for the calibration of mass standards.PTB-Bericht,PTB-MA-52,Braunschweig,Januar 1997.
    [12]BS EN 14907-2005 Ambient air quality.Standard gravimetric measurement method for the determination of the PM2.5 mass fraction of suspended particulate matter[S].
    [13]JIS Z8814-1994[S].小流量空气采样器.
    [14]Organisation Internationale De Metrologie Legale International Recommendation(OIML R 76-1).Nonautomatic weighing instruments Part 1:Metrological and technical requirements-Tests.
    [15]Standard operating procedure for particulate matter gravimetric analysis[S].RTI,2008.
    [16]苏文进,汪利明,翁少凡,等.天平室温度和湿度的变化对测尘滤膜称量结果的影响[J].中华劳动卫生职业病杂志,2008,26(4):198—202.
    [17]覃鸿钰,翟崇治,等.环境湿度对石英滤膜称重结果的影响[J].三门峡环境与生态,2013,3(35):21—24.
    [18]王晓彦,杜丽,等.PM_(2.5),手工监测技术要点探讨[J].中国环境监测,2014,30(4):146—150.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700