Determination of Arsenic, Antimony in Hot Spring Water Samples by Hydride Generation—Atomic Fluorescence Spectrometry
详细信息   
摘要
Using the double-channel-atomic-fluorescence spectrophotometer, AFS-820, the authors simultaneously determine the contents of trace element of Arsenic and Antimony by Hydride Generation—Atomic Fluorescence Spectrometry of water samples in hot spring of Dagunguo and Dieshuihe in Tengchong volcanic area. The results show that the content of As is higher in the Dagunguo spot, and the average value of As is 867.50 μg/L and that of Sb is 30.06 μg/L. The content of Dieshuihe spot contains minimal As, and Sb is not detected.