Continuous field estimation of dissolved organic carbon concentration and biochemical oxygen demand using dual-wavelength fluorescence, turbidity and temperature
详细信息    查看全文
文摘
Dissolved organic matter (DOM) quality and quantity is not measured routinely m>in-situm> limiting our ability to quantify DOM process dynamics. This is problematic given legislative obligations to determine event based variability; however, recent advances in field deployable optical sensing technology provide the opportunity to address this problem. In this paper, we outline a new approach for m>in-situm> quantification of DOM quantity (Dissolved Organic Carbon: DOC) and a component of quality (Biochemical Oxygen Demand: BOD) using a multi-wavelength, through-flow fluorescence sensor. The sensor measured tryptophan-like (Peak T) and humic-like (Peak C) fluorescence, alongside water temperature and turbidity. Laboratory derived coefficients were developed to compensate for thermal quenching and turbidity interference (i.e., light attenuation and scattering). Field tests were undertaken on an urban river with ageing wastewater and stormwater infrastructure (Bourn Brook; Birmingham, UK). Sensor output was validated against laboratory determinations of DOC and BOD collected by discrete grab sampling during baseflow and stormflow conditions. Data driven regression models were then compared to laboratory correction methods. A combination of temperature and turbidity compensated Peak T and Peak C was found to be a good predictor of DOC concentration (m>Rm>2 = 0.92). Conversely, using temperature and turbidity correction coefficients provided low predictive power for BOD (m>Rm>2 = 0.46 and m>Rm>2 = 0.51, for Peak C and T, respectively). For this study system, turbidity appeared to be a reasonable proxy for BOD, m>Rm>2 = 0.86. However, a linear mixed effect model with temperature compensated Peak T and turbidity provided a robust BOD prediction (m>Rm>2 = 0.95). These findings indicate that with careful initial calibration, multi-wavelength fluorescence, coupled with turbidity, and temperature provides a feasible proxy for continuous, m>in-situm> measurement of DOC concentration and BOD. This approach represents a cost effective monitoring solution, particularly when compared to UV – absorbance sensors and DOC analysers, and could be readily adopted for research and industrial applications.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700