A standardized search strategy was performed and identified 12 trials comparing AV and/or VV delay optimization and conventional CRT device programming and their effects on various clinical and echocardiographic outcomes. Pooled odds ratios were analyzed using random-effect meta-analysis with Mantel-Haenszel method.
Combined data from a total of 4,356 patients with heart failure treated with CRT showed no differences in clinical or echocardiographic outcomes between patients who underwent AV and/or VV delay optimization and patients who underwent empiric device programming (Mantel-Haenszel odds ratio 0.86 [95 % CI 0.68-1.09], P value for overall effect = .21 by intention-to-treat analysis).
The current literature suggests that routine AV and/or VV delay optimization has a neutral effect on clinical and echocardiographic outcomes based on pooled data from randomized and nonrandomized studies. Standardization of patient selection and optimization timing and method may help to further define the role of CRT device optimization.