The TSI PORTACOUNT Plus and N95 Companion accessory were used for all tests. After qualifying by passing a standard Occupational Safety and Health Administration fit test, subjects performed up to 20 consecutive tests on an individual FFR sample using a modified protocol. Regression analyses were performed for the percentage of donnings resulting in fit factors (FFs) ?00 for all 6 FFR models combined.
Regression analyses showed statistical significance for donning groups 1-10, 1-15, and 1-20. The mean percentage of donnings with an FF ?00 was 81 % -93 % for donning group 1-5, but dropped to 53 % -75 % for donning group 16-20.
Our results show that multiple donnings had a model-dependent impact on fit for the 6 N95 models evaluated. The?data suggest that 5 consecutive donnings can be performed before FFs consistently drop below 100.