Participants with and without diabetes who met current guidelines for vascular screening were recruited, and CWD waveforms, an ABI and a TBI were obtained from the right lower limb. Diagnostic accuracy was determined using colour duplex ultrasound (CFDU). Receiver operating characteristic curves were calculated.
117 participants were recruited, seventy-two with diabetes and forty-five without diabetes. CWD had the highest sensitivity in people with diabetes (74%) and without (84%). CWD also had the highest specificity in people with diabetes (74%) and without (84%) compared to both TBI and ABI. In participants with diabetes, the ABI was a poor test, area under the curve: 0.58 (p = 0.27).
CWD waveform is more likely to detect significant PAD compared to ABI and TBI in people with and without diabetes.