A new structure for gas turbine trailing edge cooling was designed. The effect of geometrical parameter on structure’s thermal performance was evaluated.
Thermochromic liquid crystal and lumped capacitance method was used to evaluate thermal performance.
The heat transfer characteristics of this structure were performed, discussed and compared with past literatures.
The overall thermal performance of this structure was evaluated and performed.