Ethylene-vinyl acetate copolymer/aluminium trihydroxide composites: A new method to predict the barrier effect during cone calorimeter tests
详细信息    查看全文
文摘
This study presents the use of oedometric compression test in order to evaluate the breakdown of a protective layer acting as a diffusion barrier (“barrier effect”) occurring during cone calorimeter tests for ethylene-vinyl acetate copolymer/aluminium trihydroxide (EVA/ATH) composites. The formation of an alumina layer at the sample surface during burning insulates thermally the underlying material and reduces the heat release rate. The efficiency of this barrier depends on the cohesion of the layer formed. This cohesion depends on the ability of the particles (ATH and synergistic mineral fillers) to self-arrange. During the test, the breakdown of this barrier can lead to an increase in HRR.

The oedometric compression test allows assessing the ability of fillers to form a cohesive layer. Results obtained from compression modulus of filler powders are directly related to some aspects of the heat release rate curve of composites measured in cone calorimeter tests. Indeed, the appearance and the intensity of the second pHRR (related to the breakdown of the barrier layer) in cone calorimeter test are related to the slope of oedometric compression curve.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700