Benchmarking Dosimetric Quality Assessment of Prostate Intensity-Modulated Radiotherapy
详细信息    查看全文
文摘
| Figures/TablesFigures/Tables | ReferencesReferences

Purpose

To benchmark the dosimetric quality assessment of prostate intensity-modulated radiotherapy and determine whether the quality is influenced by disease or treatment factors.

Patients and Methods

We retrospectively analyzed the data from 155 consecutive men treated radically for prostate cancer using intensity-modulated radiotherapy to 78 Gy between January 2007 and March 2009 across six radiotherapy treatment centers. The plan quality was determined by the measures of coverage, homogeneity, and conformity. Tumor coverage was measured using the planning target volume (PTV) receiving 95 % and 100 % of the prescribed dose (V95 % and V100 % , respectively) and the clinical target volume (CTV) receiving 95 % and 100 % of the prescribed dose. Homogeneity was measured using the sigma index of the PTV and CTV. Conformity was measured using the lesion coverage factor, healthy tissue conformity index, and the conformity number. Multivariate regression models were created to determine the relationship between these and T stage, risk status, androgen deprivation therapy use, treatment center, planning system, and treatment date.

Results

The largest discriminatory measurements of coverage, homogeneity, and conformity were the PTV V95 % , PTV sigma index, and conformity number. The mean PTV V95 % was 92.5 % (95 % confidence interval, 91.3?3.7 % ). The mean PTV sigma index was 2.10 Gy (95 % confidence interval, 1.90?.20). The mean conformity number was 0.78 (95 % confidence interval, 0.76?.79). The treatment center independently influenced the coverage, homogeneity, and conformity (all p < .0001). The planning system independently influenced homogeneity (p = .038) and conformity (p = .021). The treatment date independently influenced the PTV V95 % only, with it being better at the start (p = .013). Risk status, T stage, and the use of androgen deprivation therapy did not influence any aspect of plan quality.

Conclusion

Our study has benchmarked measures of coverage, homogeneity, and conformity for the treatment of prostate cancer using IMRT. The differences seen between centers and planning systems and the coverage deterioration over time highlight the need for every center to determine their own benchmarks and apply clinical vigilance with respect to maintaining these through quality assurance.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700