Ground secondary vortex produced by the flow separation and stratification
Pollutants are accumulated at ground level due to the intervals of buildings.
Multi-vortex flow regime could delay pedestrian level pollutant dilution.
AER and Ri could be correlated by the polynomial functions.
Retention time and Ri could be correlated for one-vortex flow regime.