Microbial control of dental unit water: Feedback on different disinfection methods experience
详细信息    查看全文
文摘
A water quality study of dental units showed biofilm and opportunistic microorganisms. We report the steps that ultimately allowed us to obtain water quality as water for standard care with no pathogens throughout all dental units. In summary, treatment with continuous disinfection associated with use of sterile water allowed us to restore the water quality at the output of dental care units while ensuring the safety of care.