Environmental effects on natural frequencies of the San Pietro bell tower in Perugia, Italy, and their removal for structural performance assessment
详细信息    查看全文
文摘
class="listitem" id="list_li0005">
class="label">•

Hygro-thermal effects on natural frequencies of a masonry bell-tower are investigated.

class="label">•

Temperature variations produce significant changes in natural frequencies.

class="label">•

Three temperature-driven types of frequency variations are observed including freezing.

class="label">•

Linear regressive models allow to accurately remove temperature effects for SHM.

class="label">•

Five environmental sensors provide the most accurate estimation of natural frequencies.