Towards high through-put biological treatment of municipal wastewater and enhanced phosphorus recovery using a hybrid microfiltration-forward osmosis membrane bioreactor with hydraulic retention time in sub-hour level
详细信息    查看全文
文摘
class="listitem" id="list_l0005">
class="label">•

High rejection FO membrane decouples contaminants retention time from HRT.

class="label">•

HRT for the treatment of municipal wastewater was reduced to minutes.

class="label">•

Reduced HRT resulted in increased treatment capacity by an order of magnitude.

class="label">•

Phosphorus recovery capacity was also increased by an order of magnitude.

class="label">•

Low HRT resulted in increased membrane fouling and reduced community diversity.