Visual and real-time loop-mediated isothermal amplification (LAMP) assays targeting pat and pmi were developed.
LAMP assays for pmi gene have been reported for the first time.
Limit of detection (LOD) of visual LAMP was up to 0.05% genetically modified (GM) content for pat and 0.1% for pmi.
Real-time LAMP efficiently detected up to 0.01% GM content within 30 min.
These assays could be employed to screen 35% of GM events approved globally.