Fukushima Unit 3 recriticality potential studied for the re-reflooding during an early in-vessel phase of the accident.
The MELCOR code applied to predict the accident progression and the core state.
The SERPENT code applied to perform the criticality safety analysis.
Re-criticality is possible for non-borated water in the case of the investigated 1F3 MELCOR model.
Data exchange framework between MELCOR and SERPENT was developed.