文摘
Dosimetric properties of the borosilicate glasses (SiO2–B2O3–Al2O3–CaO–Na2O type) doped with Eu2O3, Gd2O3 and CeO2 rare earth oxides were investigated as potential materials for e-beam radiation dose measurement purposes. Glasses were prepared by classical melt-quench methodology with varying concentration of rare earth metal oxides from 0.5% to 1.5%. Linear electron accelerator was used for irradiation (17 ns or 4 μs duration pulsed mode). For lower dose range investigated (up to 900 Gy) all samples studied exhibit good dosimetric response vs. dose absorbed, whereas for higher dose range (up to 30 kGy), only materials doped with 0.5% and 1.5% of Gd2O3, as well as 0.5% CeO2 doped glasses were able to provide reproducible dosimetric response. Significant dose sensitivity variation was observed for all investigated glasses, which was dependent both on the rare earth metal concentration and the dose rate of radiation used for signal generation. For irradiated 0.5% Eu2O3, Gd2O3 and CeO2 doped glasses spectrally-resolved thermoluminescence measurements were performed. Results suggest different traps formation and stabilization mechanisms for each dopant, indicating Eu3+→Eu2+ ions reduction with simultaneous traps number consumption, glass network modification and traps stabilization for Gd2O3 doped glass and direct reduction of Ce4+→Ce3+ with simultaneous glass network disruption and increasing number of low energy traps. All investigated glass samples can be considered as potential dosimetric materials for electron beam delivered dose within the dose range up to 900 Gy and with some limitations, regarding higher doses up to 15 kGy.