Impact of Transcatheter Aortic Valve Replacement on Surgical Volumes and Outcomes in a Tertiary Academic Cardiac Surgical Practice
详细信息    查看全文
文摘
Transcatheter aortic valve replacement (TAVR) was FDA approved for the Sapien valve (Edwards Lifesciences) in the United States in November 2011. We sought to examine the impact of TAVR post-FDA approval on aortic valve surgery at our institution.

Study Design

Prospective data were collected on 573 consecutive patients that underwent surgical aortic valve replacement (SAVR) or TAVR with either the Sapien or Sapien XT from January 1, 2009 through December 31, 2014.

Results

Patients were divided into the following groups: SAVR before TAVR (n = 215), SAVR post TAVR (n = 163), and TAVR (n = 195). The 30-day mortality was not different among the 3 groups, but the mortality for the SAVR post TAVR group was better than the SAVR before TAVR group (p = 0.03). Postoperative hospital length of stay, ventilation hours, and atrial fibrillation were all decreased in the TAVR group. The number of isolated SAVRs increased after TAVR from 60 per year in group 1 to 67 per year in group 2. The total number of all isolated aortic valve procedures (SAVR + TAVR) increased from 60 per year to 177 per year. The TAVR group was divided into the following subgroups to examine the procedural learning curve: patients 1 to 50, patients 51 to 100, and patients 101 to 195. Mortality was higher in group 1 (8%) vs group 2 (0%) and group 3 (1%).

Conclusions

Since initiation of the TAVR program at our institution, the total number of aortic valve procedures has increased. Transcatheter aortic valve replacement patients had more preoperative comorbidities, but no difference in postoperative morbidity or mortality and shorter length of stay. Transcatheter aortic valve replacement mortality has continued to improve since the inception of the program.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700