Thermal strains are related to microcracking during cryogenic cooling of concretes.
Strong correlation existed between thermal strain rate and AE cumulative hits rate.
The average CTE of the trap rock concrete mixture was close to that of 9% Ni steel.
Suitability of trap rock aggregate concrete for direct LNG containment is shown.