Bipolar plates with varying channel dimensions were designed and tested.
Both interdigitated and parallel flow fields were examined to determine differences.
The optimal channel dimension size is smaller than current designs.
Channel & land width is the most important design parameter for parallel flow fields.
Stoichiometry is the most important parameter for interdigitated flow fields.