The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium
详细信息    查看全文
文摘
Polyetheretherketone (PEEK) is used as an alternative to titanium in medical devices. Previous in vitro studies examining PEEK have differed in their choice of polymer variant [PEEK or carbon-fiber reinforced PEEK (CFR-PEEK)], source of polymer (some of which are no longer available or for implantation) and cell type. While all studies demonstrated favorable cytocompatibility of the PEEK material, no studies are available which reflect the current state of the art of the material. Here, we use different forms of the only implantable grade PEEK available. These are compared with commercially pure titanium (cpTi) Grade 1 using a human primary osteoblast model. Sample materials were presented as industrially relevant surfaces. Machined or injection molded PEEK and CFR-PEEK were evaluated along with polished (Ra = 0.200 μm) and rough (Ra = 0.554 μm) cpTi. Osteoblast adhesion at 4 h on injection molded variants of PEEK (Ra = 0.095 μm) and CFR-PEEK (Ra = 0.350 μm) material was comparable to titanium. Machined variants of PEEK (Ra = 0.902 μm) and CFR-PEEK (Ra = 1.106 μm) materials were significantly less. Proliferation at 48 h determined by [3H]-thymidine incorporation was the greatest on the smoothest of all materials, the injection molded unfilled PEEK, which was significantly higher than the rough titanium control. The machined unfilled PEEK had the lowest DNA synthesis. RT-PCR for alkaline phosphatase, Type I collagen and osteocalcin normalized to glyceraldehyde-3-phosphate dehydrogenase revealed different patterns of mRNA levels. High mRNA levels for Type I collagen showed that CFR-PEEK stimulated osteoblast differentiation, whilst injection molded unfilled PEEK was less differentiated. Machined unfilled PEEK had comparable message levels of bone matrix proteins as rough titanium. All material variants permitted a degree of mineralization. Scanning electron microscopy at 3 days and 2 weeks in differentiation medium showed that human osteoblasts were well spread on all the different substrates. The varied response reported here at different time points during the study suggests that material formulation (unfilled PEEK or CFR-PEEK), subjection to industrial processing, surface roughness and topography may all influence the cellular response of osteoblasts to PEEK. Thus, differences in human osteoblast responses were found to the various samples of PEEK, but implantable grade PEEK, in general, was comparable in vitro to the bone forming capacity of rough titanium.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700