We enrolled 2,727 consecutive patients presenting with suspected AMI without persistent ST-segment elevation to the emergency department in a prospective international multicenter study. The final diagnosis was adjudicated by 2 independent cardiologists. The performance of the 0 h/3 h rule out protocol was evaluated using 4 high-sensitivity (primary analysis) and 3 sensitive cardiac troponin (cTn) assays.
Acute myocardial infarction was the final diagnosis in 473 patients (17.3%). Using the 4 high-sensitivity cTn assays, the 0-hour rule out protocol correctly ruled out 99.8% (95% [confidence interval] CI, 98.7%-100%), 99.6% (95% CI, 98.5%-99.9%), 100% (95% CI, 97.9%-100%), and 100% (95% CI, 98.0%-100%) of late presenters (>6 h from chest pain onset). The 3-hour rule out protocol correctly ruled out 99.9% (95% CI, 99.1%-100%), 99.5% (95% CI, 98.3%-99.9%), 100% (95% CI, 98.1%-100%), and 100% (95% CI, 98.2%-100%) of early presenters (<6 h from chest pain onset). Using the 3 sensitive cTn assays, the 0-hour rule out protocol correctly ruled out 99.6% (95% CI, 98.6%-99.9%), 99.0% (95% CI, 96.9%-99.7%), and 99.1% (95% CI, 97.2%-99.8%) of late presenters; and the 3-hour rule out protocol correctly ruled out 99.4% (95% CI, 98.3%-99.8%), 99.2% (95% CI, 97.3%-99.8%), and 99.0% (95% CI, 97.2%-99.7%) of early presenters. Overall, the 0 h/3 h rule out protocol assigned 40% to 60% of patients to rule out. None of the patients assigned rule out died during 3-months follow-up.
The 0 h/3 h rule out protocol seems to allow the accurate rule out of AMI using both high-sensitivity and sensitive cTn measurements in conjunction with clinical assessment. Additional studies are warranted for external validation.