文摘
Aquamid represents a new generation of soft-tissue fillers for aesthetic facial correction and reconstruction due to its reduced quantity of particles (2.5 % of polyacrylamide) and high concentration of water (97.5 % ). It is a biocompatible, atoxic, homogeneous, and stable product. Additionally, it has good viscosity and elasticity, and it is very simple to use. Although reported in less than 1 % of the cases, adverse effects such as pain, swelling, and erythema may occur, which may be the result of inappropriate injection procedure. This article reports the first case of an intraoral foreign body reaction resulting from Aquamid application in the nasolabial fold. Possible causes for this reaction, the chemical composition of the product, and the histopathologic aspects are discussed.