Corrosion of galvanised steel under an electrolytic drop
详细信息    查看全文
文摘
Described here for the first time is an investigation of the local corrosion behaviour of galvanized steel using an electrolytic droplet comprising chloride and sulphate ions. The maximal height of the electrolytic layer and the diameter varied between 500–1100 μm with a total diameter between 1.47–3.35 mm, respectively. These measurements were possible by using microelectrodes as reference and counter electrodes, which could be inserted into the electrolyte droplet thus forming an electrochemical microcell. Polarization curves as well as electrochemical impedance spectroscopy plots were recorded under the electrolyte droplet configuration allowing the determination of the polarisation resistance Rp and the proportionality constant k of the Stern and Geary equation. The influence of temperature, chloride concentration, pH and the thickness of the electrolytic layer on the corrosion rate of galvanised steel were studied.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700