Mercury and SO3 emissions were measured at the Callide Oxy-fuel Project.
Measurements were taken during transitions between air and oxy-firing.
The use of low NOx burners significantly reduced mercury emissions.
Mercury capture rates were estimated at 92–99% in oxy-firing.
Low SO3 values were suggested due to acid condensation in a prior heat exchanger.