Two open-source simulators were developed for DCMD module scale-up.
A coupled “tanks-in-series” and “black box” approach was developed.
The developed simulators offer good accuracy.
Profiles of major DCMD parameters versus membrane length were obtained.
Key DCMD module scale-up criteria were identified and evaluated.