Optimisation of chromatographic conditions for the determination of folates in foods and biological tissues for nutritional and clinical work
详细信息    查看全文
文摘
Recent studies implicate folate metabolism in the aetiology of heart disease, neural tube defects, malignant transformation and affective disorders. The paper reports a rapid, isocratic HPLC separation of 11 folylmonoglutamate compounds which should prove useful when adapted to the varied needs of analysts researching these and other specific areas. Also reported are the separation, UV spectra including λmax values, fluorescence emission scans at an excitation wavelength of 295 nm and electrochemically derived hydrodynamic voltammograms with optimum oxidation voltages for p-aminobenzoylglutamate, tetrahydrofolate, 5-methyldihydrofolate, 5-methyltetrahydrofolate, 5-formyltetrahydrofolate, 5,10-methenyltetrahydrofolate, dihydrofolate, pteroylmonoglutamate and 5,10-methylenetetrahydrofolate. In particular, 5-methyltetrahydrofolate, the main food folate and form of the vitamin found in plasma, can be measured easily by electrochemical detection using a low and highly selective voltage of 450 mV. This reduced folate is also readily detected fluorimetrically using an excitation wavelength of 295 nm and measuring emission at 365 nm. Electrochemical and fluorimetric detection offer equal sensitivity for 5-methyltetrahydrofolate measurement (300 pg on column). No other folate studied could be measured down to this level using fluorimetric detection under the described conditions. At pH 3·5, folate coenzyme λmax for UV detection varies between 267 and 300 nm with 5,10-methenyltetrahydrofolate giving maximum absorption at 355 nm. UV measurement of 5-methyltetrahydrofolate is approaching an order of magnitude less sensitive than the former methods of detection. However, for in vitro studies, particularly in the form of a photodiode array, UV detection is a particularly useful tool. For cerebrospinal fluid, plasma, erythrocyte or food measurement of 5CH3-H4PteGlu, electrochemical or fluorimetric detection is recommended; whilst for pharmacokinetic studies of plasma 5CHO-H4PteGlu during methotrexate rescue therapy, electrochemical or UV detection is most appropriate. For analysis of plasma PteGlu following supplementation, or in food stuffs, UV detection offers the best measurement technique. The information presented should help address the major problem of trace folate analysis by HPLC, that is the need to combine high sensitivity with optimum selectivity in studying complex matrices such as physiological fluids, tissue preparations and food samples.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700