The Effect of Postoperative Face-Down Positioning and of Long- versus Short-Acting Gas in Macular Hole Surgery: Results of a Registry-Based Study
详细信息    查看全文
文摘
To determine whether sulfur hexafluoride (SF6) gas is noninferior to longer-acting gases in macular hole surgery and whether withholding postoperative face-down positioning (FDP) is noninferior to FDP.

Design

Registry-style, prospective, nonrandomized, observational cohort study.

Participants

Patients with idiopathic macular holes undergoing primary surgery.

Methods

Surgeons were invited to submit clinical details of all macular hole cases receiving surgery. Baseline demographic and clinical information were collected, as well as details of surgical intervention and postoperative posturing advice. Primary follow-up data were collected 3 months postoperatively.

Main Outcome Measures

Macular hole closure at 3 months. A noninferiority approach was used, with a noninferiority margin set at 5% decreased frequency of success.

Results

A total of 2456 eyes of 2367 patients were included in the study. Outcomes were available in 94.9% of cases (2330/2456). The rate of macular hole closure was 95.0% (2214/2330). Sulfur hexafluoride gas was found to be noninferior to longer-acting gases (95% confidence interval [CI] for adjusted effect on success, −1.76 to +2.25), and noninferiority was demonstrated regardless of macular hole size. Although withholding FDP was found to be noninferior to FDP for the study population as a whole (95% CI for adjusted effect on success, −4.21 to +0.64), the result was inconclusive in holes >400 μm in diameter (95% CI, −9.31 to +1.04). Lack of internal limiting membrane (ILM) peel, increasing hole size, hole duration ≥9 months, increasing age, and 20-gauge surgery all were associated with lower odds of success. Vitreous attachment to the hole margin was not associated with outcome when corrected for hole size, and combined phacovitrectomy surgery was not observed to affect the odds of success in phakic eyes.

Conclusions

Sulfur hexafluoride gas tamponade was noninferior to longer-acting gases in the surgical management of macular hole. Withholding FDP was noninferior to FDP in holes ≤400 μm in diameter. In holes >400 μm in diameter, noninferiority of withholding FDP could not be concluded. We would advise caution if posturing is withheld in this group on the basis of the results of this study and of others.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700