The pre-coagulated leachate membrane concentrates were treated by Fenton process. Impact of Fenton reagent dosing method on H2O2 utilization efficiency was explored. Continuous addition of Fenton reagents improved the TOC removal efficiency. The composition of contaminants removed during Fenton process was analyzed in detail. The major removed organic material by Fenton process was humic acid.