SOFC dynamic model was based on electro-chemical and enthalpy balance relations.
Model regulates SOFC temperature at a fixed value adjusting air utilization factor.
The model was tuned and validated based on experimental data.
A delay about 20–25 s was determined in inlet air flow rate regulation.
Model permits to reduce system thermal stresses in load following operation.