Biomechanical comparison of plate and screw fixation in anterior pelvic ring fractures with low bone mineral density
详细信息    查看全文
文摘
Osteosynthesis of anterior pubic ramus fractures can be challenging, especially in poor bone quality. The aim of the present study was to compare plate and retrograde endomedullary screw fixation of the superior pubic ramus with low bone mineral density (BMD).

Materials and methods

Twelve human cadaveric hemi-pelvises were analyzed in a matched pair study design. BMD of the specimens was 35 ± 30 mgHA/cm3, as measured in the fifth lumbar vertebra. A simulated two-fragment superior pubic ramus fracture model was fixed with either a 7.3-mm cannulated retrograde screw (Group 1) or a 10-hole 3.5-mm reconstruction plate (Group 2). Cyclic progressively increasing axial loading was applied through the acetabulum. Relative interfragmentary movements were captured using an optical motion tracking system.

Results

Initial axial construct stiffness was 424 ± 116.1 N/mm in Group 1 and 464 ± 69.7 N/mm in Group 2, with no significant difference (p = 0.345). Displacement and gap angle at the fracture site during cyclic loading were significantly higher in Group 1 compared to Group 2. Cycles to failure, based on clinically relevant criteria, were significantly lower in Group 1 (3469 ± 1837) compared to Group 2 (10,226 ± 3295) (p = 0.028). Failure mode in Group 1 was characterized by screw cutting through the cancellous bone. In Group 2 the specimens exclusively failed by plate bending.

Conclusions

From biomechanical point of view, pubic ramus stabilization with plate osteosynthesis is superior compared to a single retrograde screw fixation in osteoporotic bone. However, the extensive surgical approach needed for plating must be considered.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700