A computerized research of MEDLINE, EMBASE, Springer, and Cochrane Library (before December 2014) for studies of any design comparing ORIF and ExFix was conducted. Weighted mean difference (WMD), risk ratio (RR) and corresponding 95% confidence intervals (CI) were used for estimating the effects of the two methods. Statistical analyses were done using Review Manager Version 5.2.
Ten cohort studies and one randomized clinical trial were included in our ultimate analysis. And the analysis found no significant difference between the two methods in deep infection (p = 0.13), reduction (p = 0.11), clinical evaluation (p = 0.82), post-traumatic arthrosis (p = 0.87), and union time (p = 0.35). Besides, ExFix group was found to have a higher rate of superficial infection (p = 0.001), malunion (p = 0.01) and nonunion (p = 0.02), but have a lower risk of unplanned hardware removal (p = 0.0002).
We suggest that ORIF has a relatively lower incidence rate of superficial infection, malunion and nonunion, but a higher rate of unplanned hardware removal. No difference was found in deep infection, reduction, clinical evaluation, post-traumatic arthrosis and union time.