Minimally invasive plate osteosynthesis using posterolateral approach for distal tibial and tibial shaft fractures
详细信息    查看全文
文摘
The objective of the study was to evaluate the effectiveness of the posterolateral minimally invasive plate osteosynthesis (MIPO) method for managing distal tibial or tibial shaft fractures with severe anterior and medial soft tissue injuries.

Materials and methods

Five consecutive patients with three distal tibial and two tibial shaft fractures (three open fractures) at a level-1 trauma and tertiary referral center were retrospectively reviewed. All patients were definitively treated and followed to bone union. Main outcome was measured by American Orthopaedic Foot and Ankle Society (AOFAS) ankle–hindfoot score, complications, and bone union on radiographs.

Results

The average follow-up period was 15.8 months (range, 12–24 months). The average AOFAS score was 88.2 (range, 81–90). There were no complications, such as incision breakdown, deep infection, or impingement of the flexor hallucis longus tendon. Bone union was achieved in all cases.

Conclusions

Posterolateral MIPO is a feasible option when treating these fractures, especially in cases with severe anterior and medial soft tissue injuries.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700