Exergetic performance assessment of a long-life milk processing plant: a comprehensive survey
详细信息    查看全文
文摘

Comprehensive exergy analysis of an industrial-scale long-life milk processing plant.

The largest exergy destruction rate in the compressor and boiler combination of the steam generator.

345.50 kJ exergy destruction in processing 1 kg of the UHT treated milk.

Potential application of exergy concept for improving the performance of dairy processing plants.