Synchronous execution of full repowering and solar assisting is evaluated. A 400 MW gas turbine is chosen for full repowering. Solar energy is used for evaporating a part of feed water in parallel with HRSG. Annual effects on fuel consumption and Decrease in CO2 emission are investigated. The effects of number of pressure levels of HRSG on cycle performance are evaluated.