Folded helical baffle electric heater with one-plus-two U-tube units is a new design.
CFD and visualization software were adopted to compare flow and heating properties.
Design and off-design performances of helical and segmental schemes were simulated.
Flow field and heat transfer coefficient verify better performance of helical heater.
Temperature homogeneity on tube surfaces of helical electric heater is demonstrated.