High Flow Nasal Cannula Use Is Associated with Increased Morbidity and Length of Hospitalization in Extremely Low Birth Weight Infants
详细信息    查看全文
文摘
To determine differences in the incidence of bronchopulmonary dysplasia (BPD) or death in extremely low birth weight infants managed on high flow nasal cannula (HFNC) vs continuous positive airway pressure (CPAP).

Study design

This is a retrospective data analysis from the Alere Neonatal Database for infants born between January 2008 and July 2013, weighing ≤1000 g at birth, and received HFNC or CPAP. Baseline demographics, clinical characteristics, and neonatal outcomes were compared between the infants who received CPAP and HFNC, or HFNC ± CPAP. Multivariable regression analysis was performed to control for the variables that differ in bivariate analysis.

Results

A total of 2487 infants met the inclusion criteria (941 CPAP group, 333 HFNC group, and 1546 HFNC ± CPAP group). The primary outcome of BPD or death was significantly higher in the HFNC group (56.8%) compared with the CPAP group (50.4%, P < .05). Similarly, adjusted odds of developing BPD or death was greater in the HFNC ± CPAP group compared with the CPAP group (OR 1.085, 95% CI 1.035-1.137, P = .001). The number of ventilator days, postnatal steroid use, days to room air, days to initiate or reach full oral feeds, and length of hospitalization were significantly higher in the HFNC and HFNC ± CPAP groups compared with the CPAP group.

Conclusions

In this retrospective study, use of HFNC in extremely low birth weight infants is associated with a higher risk of death or BPD, increased respiratory morbidities, delayed oral feeding, and prolonged hospitalization. A large clinical trial is needed to evaluate long-term safety and efficacy of HFNC in preterm infants.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700