Unbound Bilirubin and Auditory Neuropathy Spectrum Disorder in Late Preterm and Term Infants with Severe Jaundice
详细信息    查看全文
文摘
This study evaluates whether unbound bilirubin is a better predictor of auditory neuropathy spectrum disorder (ANSD) than total serum bilirubin (TSB) or the bilirubin:albumin molar ratio (BAMR) in late preterm and term neonates with severe jaundice (TSB ≥20 mg/dL or TSB that met exchange transfusion criteria).

Study design

Infants ≥34 weeks' gestation with severe jaundice during the first 2 weeks of life were eligible for the prospective observational study. A comprehensive auditory evaluation was performed within 72 hours of peak TSB. ANSD was defined as absent or abnormal auditory brainstem evoked response waveform morphology at 80-decibel click intensity in the presence of normal outer hair cell function. TSB, serum albumin, and unbound bilirubin were measured using the colorimetric, bromocresol green, and modified peroxidase method, respectively.

Results

Five of 44 infants developed ANSD. By logistic regression, peak unbound bilirubin but not peak TSB or peak BAMR was associated with ANSD (OR, 4.6; 95% CI, 1.6-13.5; P = .002). On comparing receiver operating characteristic curves, the area under the curve for unbound bilirubin (0.92) was significantly greater (P = .04) compared with the area under the curve for TSB (0.50) or BAMR (0.62).

Conclusions

Unbound bilirubin is a more sensitive and specific predictor of ANSD than TSB or BAMR in late preterm and term infants with severe jaundice.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700