Flow mixings inside a wire-wrapped 37-pin bundle were measured using a wire-mesh sensing system.
A proper post-processing method was developed for the results.
Experiments were carried out in the condition of 20–115% Re of the prototype reactor nominal flow.
The identified mixing characteristics showed pretty good match with the CFD results.