Operation strategy of hybrid-SIT (H-SIT) in station blackout (SBO) is developed.
There are five main factors which have to be carefully treated in the development of the operation strategy.
Optimal value of each main factor is investigated analytically and then through thermal-hydraulic analysis using computer code.
The optimum operation strategy is suggested based on the optimal value of the main factors.