Modeling of mercuric chloride removal in ductwork and fabric filter by raw activated carbon injection
详细信息    查看全文
文摘

Model for HgCl2 capture by raw AC sorbent in ductwork and FF was developed.

Adsorption kinetics/equilibrium, mass transfer and operating parameters considered.

Internal mass transfer, sorbent size and loading determine in-flight capture.

Sorbent size is the most important parameter in FF capture.

Pressure drop for 20-μm fly ash is manageable up to 90-min cleaning cycle.