id="p0010">Three gradient-free methods are applied to optimisation of an advanced ultra-supercritical power plant unit.
id="p0015">Thirteen decision parameters are considered in the optimisation process.
id="p0020">Computing time for each of the optimisation method is analysed.
id="p0025">Rise in efficiency by 0.34 percentage points in comparison with the reference plant is achieved.