Crack characterisation of absorber tubes in CSP plants using EMATs is developed.
An feature invariable to factors e.g. electromagnetic coupling, lift-off is found.
The feature Ac2/Ae1 has linear relationship with the depth of the crack.
The invariable feature requires no calibration of EMAT system for various tubes.