Noise reduction of ultrasonic Doppler velocimetry in liquid metal experiments with high magnetic fields
详细信息    查看全文
文摘
The last decades have seen a number of liquid metal experiments on the interaction of magnetic fields with the flow of electrically conducting fluids. The opaqueness of liquid metals requires non-optical methods for inferring the velocity structure of the flow. Quite often, such experiments are carried out in the presence of high electrical currents to generate the necessary magnetic fields. Depending on the specific purpose, these currents can reach several kiloamperes. The utilized switching mode power supply can then influence seriously the measurement system by electromagnetic interference. A recent experiment on the azimuthal magnetorotational instability (AMRI) has shown that a hydrodynamically stable Taylor–Couette flow becomes unstable under the influence of a high azimuthal magnetic field. An electrical current along the axis of the experiment with up to 20 kA generates the necessary field to destabilize the flow. We present experimental results of this AMRI experiment carried out at the PROMISE facility with an enhanced power supply. For this setup, we discuss the elaborate measures that were needed to obtain a reasonable signal-to-noise ratio of the ultrasonic Doppler velocimetry (UDV) system. In dependence on various parameter variations, some typical features of the observed instability, such as the energy content, the wavelength, and the frequency are analyzed and compared with theoretical predictions.