Liquid chromatography–tandem mass spectrometry for the simultaneous quantitation of artemether and lumefantrine in human plasma: Application for a pharmacokinetic study
详细信息    查看全文
文摘
A liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS/MS) method for the simultaneous quantitation of artemether and lumefantrine in human plasma was developed and validated. Artesunate was used as an internal standard (IS). The analytes were extracted by a protein precipitation procedure and separated on a reversed-phase Zorbax SB-Ciano column with a mobile phase composed of methanol and 10 mM aqueous ammonium acetate containing 0.2 % (v/v) acetic acid and 0.1 % (v/v) formic acid. Multiple reaction monitoring was performed using the transitions m/z 316 → m/z 267, m/z 530 → m/z 348 and m/z 402 → m/z 267 to quantify artemether, lumefantrine and artesunate, respectively. Calibration curves were constructed over the range of 10–1000 ng/mL for artemether and 10–18,000 ng/mL for lumefantrine. The lower limit of quantitation was 10 ng/mL for both drugs. The mean R.S.D. values for the intra-run precision were 2.6 % and 3.0 % and for the inter-run precision were 3.6 % and 4.6 % for artemether and lumefantrine, respectively. The mean accuracy values were 102.0 % and 101.2 % for artemether and lumefantrine, respectively. No matrix effect was detected in the samples. The validated method was successfully applied to determine the plasma concentrations of artemether and lumefantrine in healthy volunteers, in a one-dose pharmacokinetic study, over the course of 11 days.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700