Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month results
详细信息    查看全文
文摘
To compare astigmatic outcomes in patients with bilateral cataracts having toric intraocular lens (IOL) implantation with intraoperative aberrometry measurements in 1 eye and standard power calculation and a toric IOL calculator with inked axis marking in the contralateral eye.

sSec_2">Setting

spara0015">Twelve sites in the United States.

sSec_3">Design

spara0020">Prospective cohort study.

sSec_4">Methods

spara0025">The eye with the more visually significant cataract was randomized to intraoperative aberrometry measurements (Ocular Response Analyzer with Verifeye) or standard preoperative biometry and use of a toric calculator with the contralateral eye automatically assigned to the other group. The primary effectiveness outcome was the proportion of eyes with a postoperative refractive astigmatism of 0.50 diopter (D) or less at 1 month.

sSec_5">Results

spara0030">Of the 130 patients (260 eyes) enrolled, 124 (248 eyes) were randomized; 121 (242 eyes) completed the trial. The percentage of eyes with astigmatism of 0.50 D or less at 1 month was higher in the intraoperative aberrometry group than in the standard group (89.2% versus 76.6%) (P = .006). The mean postoperative refractive astigmatism was lower in the intraoperative aberrometry group (0.29 D ± 0.28 [SD] versus 0.36 ± 0.35 D) (P = .041). Secondary effectiveness endpoints, including manifest refraction spherical equivalent prediction error, uncorrected distance visual acuity, and corrected distance visual acuity, were similar.

sSec_6">Conclusions

spara0035">Compared with standard methods, the use of the intraoperative aberrometry system increased the proportion of eyes with postoperative refractive astigmatism of 0.50 D or less and reduced the mean postoperative refractive astigmatism at 1 month. Other efficacy outcomes were similar.

sSec_7">Financial Disclosures

spara0040">Drs. Woodcock, Lehmann, and Cionni are consultants to Alcon Laboratories, Inc. Dr. Breen is an employee of Alcon Laboratories, Inc. Dr. Scott has no financial or proprietary interest in any material or method mentioned.