Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material
详细信息    查看全文
文摘

Statement of problem

Wear resistance is one of the most important physical properties of artificial resin teeth, and its dependence on the antagonist material has not been clearly established.

Purpose

The purpose of this in vitro study was to investigate the wear resistance of representative artificial resin teeth in relation to antagonist material.

Material and methods

Twenty-four standardized specimens were prepared for each of 8 tooth types representative of anterior and posterior artificial acrylic and composite resin teeth (Gnathostar, SR Orthosit PE, Condyloform II NFC, SR Postaris DCL, SR Vivodent PE, VITA Physiodens, SR Antaris DCL, Bioplus), for a total of 192 specimens. Each specimen was prepared to a diameter of 5 mm and a thickness of 2 mm on the buccal/facial tooth surfaces. The specimens were then polished and subjected to simulated mastication (50 N, 1.2 × 105 cycles, 1.2 Hz) using a pin-on-block design and additional thermocycling (600 cycles, 5/55°C, 2 min/cycle). Three antagonists (artificial resin teeth, steel, steatite) were prepared, and 8 specimens per tooth type were tested for each antagonist. Vertical substance and volume loss were analyzed using cast replicas and an optical 3-dimensional (3-D) surface profilometer, as well as scanning electron microscopy. Data were analyzed using 2- and 1-way ANOVA and the Games-Howell test (α=.05).

Results

For both vertical substance and volume loss, significant differences were found for the various antagonists. Lowest overall mean values (SD) for vertical substance and volume loss were measured for artificial tooth antagonists (26 (10) μm to 95 (46) μm, 1.5 (1.5) μm3 to 10.5 (9) μm3), and the highest values were measured for steatite antagonists (95 (23) μm to 723 (168) μm, 8 (4) μm3 to 245 (109) μm3). Intermediate mean values (SD) for vertical substance and volume loss were measured for steel antagonists (118 (88) μm to 205 (120) μm, 9 (7) μm3 to 28 (24) μm3). Using artificial teeth and steel antagonists, few significant differences in wear resistance were found between the various resin teeth. In contrast, significant differences were observed with steatite antagonists.

Conclusions

The use of steatite antagonists allowed for significantly better differentiation of wear behavior between various artificial teeth than the use of artificial resin teeth or steel antagonists. (J Prosthet Dent 2009;101:269-278)

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700