Two-body wear of dental restorative materials
详细信息    查看全文
文摘
Aim: The aim of this in vitro study was to determine the two-body wear resistance of modern direct dental restorative materials.

Methods: Eight standardized specimens were prepared from 14 dental restorative materials (nano-, micro-, hybrid-, macrofilled composites; compomer, silorane, ormocer); a veneering composite (Sinfony) and enamel were used for reference. Vickers hardness (HV) and inorganic filler weight were determined. Specimens were subjected to mastication simulation using a mastication simulator (50 N, 1.2¡Á105 cycles, 1.2?Hz) in a pin-on-block design and simultaneous thermal cycling (600 cycles, 5/55?¡ãC, 2 min/cycle). Steatite balls were used as antagonists. Vertical substance and volume loss were determined using cast replicas and a 3D laser scanning device. Means and standard deviations were calculated, and statistical analysis was performed using one-way ANOVA and the Games¨CHowell test for post hoc analysis .

Results: HV ranged between 19 and 76; inorganic filler weight ranged between 44 % and 88 % . Significantly lowest vertical substance and volume loss were detected for the microfilled composite Heliomolar; enamel yielded similar vertical substance and volume loss. Intermediate wear was found for the other microfilled and hybrid composites as well as the silorane and the ormocers. Significantly highest wear was found for the macrofilled composite Quixfil and the compomer Compoglass F.

Discussion: Within the limitations of an in vitro study, the findings indicate similar wear behaviour for silorane- and ormocer-based dental restorative materials. However, correlations between HV, filler content, and wear resistance were poor.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700