Effect of Distributor Design on Gas-Liquid Distribution in Monolithic Bed at High Gas/Liquid Ratios
详细信息    查看全文
文摘
Experiments were carried out to investigate the liquid flow distribution at high gas/liquid ratios in a cold model monolith bed of a 0.048 m diameter with 62 cells per cm2. Three types of distributor for the liquid distribution were used to evaluate their distribution performance. Local liquid saturation in individual channels was measured using 16 single-point optical fiber probes mounted inside the channels. The results indicate that 1) The optical fiber probe technique can measure phase distribution in the monolith bed; 2) Liquid saturation distribution along the radial direction of the monolith bed is not uniform and the extent of non-uniformity depends on the distributor design and phase velocities; and 3) The tube array distributor provides superior liquid distribution performance over the showerhead and nozzle distributors.