刊名:Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
出版年:2016
出版时间:11 September 2016
年:2016
卷:830
期:Complete
页码:182-190
全文大小:1916 K
文摘
We report the results of three MRPC detectors built with soda lime glass and tested in the T10 beam line at CERN. The detectors consist of a stack of 280 μm thick glass sheets with 6 gaps of . We built two identical MRPCs, except one had the edges of glass treated with resistive paint. A third detector was built with one HV electrode painted as strips. The detectors' efficiency and time resolution were studied at different particle flux in a pulsed beam environment. The results do not show any improvement with the painted edge technique at higher particle flux. We heated the MRPCs up to 40 °C to evaluate the influence of temperature in the rate capability. Results from this warming has indicated an improvement on the rate capability. The dark count rates show a significant dependence with the temperature.