This study sought to determine the incidence, timing, and predictors of VHD in a large cohort of patients undergoing TAVR.
This multicenter registry included 1,521 patients (48% male; 80 ± 7 years of age) who underwent TAVR. Mean echocardiographic follow-up was 20 ± 13 months (minimum: 6 months). Echocardiographic examinations were performed at discharge, at 6 to 12 months, and yearly thereafter. Annualized changes in mean gradient (mm Hg/year) were calculated by dividing the difference between the mean gradient at last follow-up and the gradient at discharge by the time between examinations. VHD was defined as a ≥10 mm Hg increase in transprosthetic mean gradient during follow-up compared with discharge assessment.
The overall mean annualized rate of transprosthetic gradient progression during follow-up was 0.30 ± 4.99 mm Hg/year. A total of 68 patients met criteria of VHD (incidence: 4.5% during follow-up). The absence of anticoagulation therapy at hospital discharge (p = 0.002), a valve-in-valve (TAVR in a surgical valve) procedure (p = 0.032), the use of a 23-mm valve (p = 0.016), and a greater body mass index (p = 0.001) were independent predictors of VHD.
There was a mild but significant increase in transvalvular gradients over time after TAVR. The lack of anticoagulation therapy, a valve-in-valve procedure, a greater body mass index, and the use of a 23-mm transcatheter valve were associated with higher rates of VHD post-TAVR. Further prospective studies are required to determine whether a specific antithrombotic therapy post-TAVR may reduce the risk of VHD.